3 phase pdu mining pdu power strip

Maikling Paglalarawan:

Ang NIngbo YOSUN High power Basic Rack Power Distribution Unit (PDU) ay namamahagi ng power sa mga device sa heavy duty environment. Ang PDU na may 12 outlet at built-in na 3phase 63A MCB(miniature circuit breaker). Ang mga AUS outlet 3 phase 63A 230V/400V PDU ay tugma sa malawak na hanay ng mga boltahe upang maghatid ng tatlong-phase na AC power sa maraming load mula sa isang utility outlet, generator o UPS system. Tamang-tama para sa mining farm, data center, server room at network wiring closet. Sinusuportahan ng all-alu housing ang iba't ibang opsyon sa pag-mount, kabilang ang 1U vertical mounting sa EIA-standard na 19-inch na rack, sa ilalim ng counter o sa dingding o workbench.


  • modelo:YS1012-3P-AUS
  • Detalye ng Produkto

    Proseso ng Produksyon

    Mga Tag ng Produkto

    Mga tampok

    • Mataas na Kalidad: Ang disenyo ng Alu housing ay matibay at matibay, at ang pagkakagawa ay mahusay, heavy duty outlet strip na may CE Certification, sumusunod sa mga pamantayan sa kaligtasan, maaari mo itong gamitin nang may kumpiyansa.
    • Suportahan ang mga customized na outlet para sa high power pdu. Tinatanggap namin ang karamihan sa mga uri ng plug mula sa buong mundo, kabilang ang: IEC C13, C19, UK, US, buong Europe, China, Australian at higit pa!
    • Ang built-in na power switch at 63 amp circuit breaker ay nag-aalok ng power control, overload na proteksyon at short circuit sa lahat ng outlet. Ang high power na pdus ay maaaring gamitin sa anumang cabinet o pagmimina, sinusuportahan din ang 125A o anumang iba pang customized na agos.

    mga detalye

    1) Sukat: 730*44.8*45mm
    2) Kulay: itim
    3) Mga Outlet :12*TYPE I Australian outlet
    4) Mga Outlet na Plastic Material: antiflaming PC module AUS
    5) Materyal sa pabahay: Aluminyo haluang metal
    6)Tampok:3P 63A circuit breaker
    7)Amps:63A /customized
    8)boltahe:230V /400V
    9)Plug: 5P IEC60309 IP44 plug / OEM
    10)Cable spec: custom

    Suporta

    1 2 3 4
    Terminal block(≤32A)10A-32A 125/250VAC Junction Box(≤32A)10A-32A 125/250VAC 1U Junction Box(Mataas na kapangyarihan)10A-63A 125A/400VAC 1.5U Junction Box(Mataas na kapangyarihan)10A-63A 125A/400VAC
    5 6 7 8
    Overload na Proteksyon10/16A 250VAC Iluminado Master Switch10A/16A 125VAC / 250VAC Overload Switch10A/16A 125VAC / 250VAC BuzzerDC 24V / 36V / 48VAC 110V / 220V
    9 10 11 12
    Earth Leakage Circuit BreakerC10/16/32/63A 1P Circuit BreakerC10/16/32/63A 2P Circuit BreakerC10/16/32/63A 3P Circuit BreakerC10/16/32/63A
    13 14 15 16
    100A/125A 3P Circuit BreakerC100A/125A 2P Circuit BreakerC10/16/32/63A USB Charger 2 * Uri A5V 2.1A USB Charger Type A+Type C5V 2.1A / 3.1A / mabilis na pag-charge
    17 18 19 20
    Tagapagpahiwatig ng kapangyarihan125V/250VAC 50/60Hz Hot-swap Power Indicator125V/250VAC 50/60Hz Single-Lamp Surge Protector4.5KA/6.5KA/10KA 250VAC 50/60Hz Tatlong-Lamp Surge Protector(Pag-filter at proteksyon ng surge)10KA 250VAC 50/60Hz
    21 22 23 24
    Hot-swap Surge protector4.5KA/6.5KA/10KA 250VAC 50/60Hz Hot-swap V/A Metro Hot-swap 485 Smart Meter Hot-swap na Smart IP Meter
    25 26 27 28
    Intelligent PDU Meter Para saoutlet monitor at kontrol 10A Universal Socket10A 250VAC 16A Universal Socket16A 250VAC 10A Chinese Socket 5 butas
     29 30  31 32
    10A Chinese Socket 16A Chinese Socket Chinese 10A/16A Socket 10A locking Chinese Socket
    33 34 35 36
    16A locking Chinese Socket IEC320 C13(Anti-trip)10A 250VAC IEC320 C1310A 250VAC IEC320 C19(Anti-trip)16A 250VAC
    37 38  39 40
    IEC320 C1916A 250VAC 16A German Socket16A 250VAC 16A French Socket16A 250VAC 16A GER.ITA Socket16A 250VAC
    41 42  43 44
    13A UK Socket13A 250VAC 15A USA Socket15A 125VAC 20A USA Socket20A 125VAC IEC320 C1416A 250VAC
    45 46 47 48
    IEC320 C2016A 250VAC 16A ZA Socket16A 250VAC IEC320 C13(2 Paraan sa isang Socket)10A 250VAC IEC320 C13(3 Paraan sa isang Socket)10A 250VAC
    49 50 51 52
    10A 250VAC 10A Chinese Plug 16A Chinese Plug IEC60309 IP44-Male(Three Core) Commando plug16A/32A/63A 250VAC
    53 54 55 56
    IEC60309 IP44-Babae(Three Core) Commando plug16A/32A/63A 250VAC IEC60309 IP44-Male(Five Core) Commando plug16A/32A/63A 250VAC IEC60309 IP44-Female(Five Core) Commando plug16A/32A/63A 250VAC UK BS1363 Plug13A 250VAC
    57 58 59 60
    German Plug16A 250VAC USA Plug15A 125VAC IEC320 C14 Plug10A 250VAC IEC320 C13Plug10A 250VAC
    61 62 63 64
    South Africa Plug16A 250VAC IEC320 C20 Plug16A 250VAC IEC320 C19 Plug16A 250VAC AUS Plug
    65
    66

    Opsyonal na Toolless na Pag-install

    67

    Available ang customized na mga kulay ng shell

    YOSUN PROCESS PRODUCTION

    Handa sa Materyal

    91d5802e2b19f06275c786e62152e3e

    Pagputol ng Pabahay

    2e6769c7f86b3070267bf3104639a5f

    Awtomatikong pagputol ng mga piraso ng tanso

    pagmamarka ng laser

    Laser Cutting

    649523fa30862d8d374eeb15ec328e9

    Awtomatikong wire stripper

    Riveted tansong wire

    Riveted tansong wire

    makina ng paghubog ng iniksyon

    Paghuhulma ng Iniksyon

    COPPER BAR WELDING

    Spot welding ng mga piraso ng tanso
    Spot welding ng copper strips (2)

    Ang panloob na istraktura ay gumagamit ng pinagsamang koneksyon sa tanso na bar, advanced na teknolohiya ng spot welding, ang kasalukuyang transmisyon ay matatag, hindi magkakaroon ng maikling circuit at iba pang mga sitwasyon

    PAG-INSTALL AT INTERIOR DISPLAY

    4

    Built-in na 270° na pagkakabukod

    Ang isang insulating layer ay naka-install sa pagitan ng mga live na bahagi at ng metal housing upang bumuo ng 270.

    Mabisang hinaharangan ng all-round na proteksyon ang pakikipag-ugnayan sa pagitan ng mga de-koryenteng bahagi at pabahay ng aluminyo haluang metal, na nagpapahusay sa antas ng kaligtasan

    I-install ang papasok na port

    Ang panloob na copper bar ay tuwid at hindi baluktot, at ang pamamahagi ng copper wire ay malinaw at malinaw

    tatlong core na kahon ng koneksyon

    PRODUCTION LINE ADD CONTROL BOARD

    matalinong kontrol

    PANGHULING PAGSUSULIT

    Ang bawat PDU ay maihahatid lamang pagkatapos maisagawa ang kasalukuyang at boltahe na mga pagsusuri sa function

    1

    PACKAGING NG PRODUKTO

    Pakete ng IP monitor
    2
    kayumanggi inbox
    pangunahing pdu packing